导读:本文包含了常压辉光放电论文开题报告文献综述、选题提纲参考文献及外文文献翻译,主要关键词:辉光,脉冲,等离子体,射频,氦气,光化学,大气压。
常压辉光放电论文文献综述
杨春,姚思琪,郑洪涛,朱振利[1](2019)在《常压辉光放电微等离子体激发源与光化学蒸气发生联用检测水体中的痕量铁》一文中研究指出基于原子发射光谱法原理(AES),通过常压辉光放电(APGD)与光化学蒸气发生(PVG)联用发展了一种简单,快速,灵敏的检测水体中痕量铁的方法。含Fe溶液与甲酸混合后进入紫外灯(UV lamp)反应生成Fe的挥发性物种,然后被载气带入到APGD激发源激发并由Maya 2000 pro微型光谱仪检测。为了获得最佳的分析性能,实验优化了氩气流速,样品流速,甲酸浓度, pH值以及放电电流等系列实验参数。Fe的发射信号强度随着氩气流速,样品流速和pH值的变化趋势都是先增大后减小,其中,氩气流速,样品流速和pH值分别为300 mL·min~(-1), 2.6 mL·min~(-1)和3.5时Fe发射信号最佳;甲酸浓度在10%~50%(V/V)范围内,随着甲酸浓度升高Fe的发射信号不断增强,但甲酸浓度过高会使APGD激发源稳定性变差,综合考虑甲酸浓度选择为40%(V/V);放电电流在10~35 mA范围内随着放电电流升高Fe的发射信号不断降低,但放电电流低于10 mA时APGD产生放电等离子体会不稳定甚至熄灭,综合考虑放电电流选择为12 mA。在最优实验条件下, PVG-APGD-AES方法检测Fe(249.8 nm)的检出限(DL)达2.1μg·L~(-1),并且方法稳定性良好,多次测定相对标准偏差(RSD)为2.5%(n=9)。实验还评估了Cd~(2+), Mg~(2+), Ca~(2+), Au~+, Zn~(2+), Mn~(2+), K~+, As~(5+), Al~(3+), Cr~(3+), Ni~(2+)和Cu~(2+)等一系列干扰元素对PVG-APGD-AES方法检测Fe的干扰,回收率在87.6%~107.2%之间,结果表明了这些共存离子不会显着干扰Fe的测定。此外,实验还通过测定Fe的标准参考物质(GSB 07-1188-2000)验证了该方法的准确性,测定值与参考值一致证明PVG-APGD-AES测定Fe是准确可靠的。上述这些结果表明所提出的简单,可靠,廉价的PVG-APGD-AES方法有望用于野外痕量Fe的检测。(本文来源于《光谱学与光谱分析》期刊2019年05期)
邓绮思,杨春,朱振利[2](2018)在《电热蒸发钨丝捕获固体进样-常压辉光放电微等离子体发射光谱测定大米中镉》一文中研究指出在30多种有毒金属元素中,镉(Cd)被列为最有毒的金属元素之一。近年来,我国农业环境镉污染日益严重,"镉大米"事件层出不穷。目前,传统的Cd检测分析方法以液体进样的光谱方法为主,但这些方法不仅仪器体积大、成本高,而且样品前处理耗时、费力。因此,发展一种快速可靠的大米Cd检测分析方法对大米产地准出、市场准入等环节监控具有重要的意义。微等离子体作为激发源在原子光谱分析领域引起了越来越多的关注,其中常压辉光放电~([1])(APGD)激发源因其体积小、功耗低、灵敏度高、供电电源简单等特点在便携式微型仪器的发展中具有一定的优势。另一方面,电热蒸发进样~([2])(ETV)因其样品引进效率高、进样量少、可实现基质分离和固体样品直接进样等优势成为原子光谱分析领域的一种良好的进样方式。本文采用电热蒸发钨丝捕获固体进样与常压辉光放电微等离子体发射光谱技术联用,建立了直接固体进样灵敏检测大米中Cd的方法。实验中探讨了灰化时间等条件的影响;考察了常见共存离子及有机基体对镉测定的干扰。该方法对大米中的Cd检出限为2.6 pg,加标回收率在94.0%~109.3%,多次测定的相对标准偏差为7.7%,可满足国家标准(GB2762-2017)对大米粮食中Cd限量的检测要求。通过对实际大米样和国家标准物质的对比检测,发现该方法检测结果与微波消解ICP-MS方法测试值无显着差别,证实了建立方法的可靠性。本文方法无需样品消解和基体改进剂及其他试剂,绿色环保,且体积小、功耗低成本低,灵敏度高、分析时间短,提供了一种新型的用于食品中重金属检测的微等离子体激发源便携式发射光谱仪器的技术方案。(本文来源于《第五届全国原子光谱及相关技术学术会议摘要集》期刊2018-09-20)
杨春,关雪迪,姚思琪,郑洪涛,朱振利[3](2018)在《便携式常压辉光放电发射光谱仪分析方法研究》一文中研究指出发射光谱法一直是实验室分析检测的重要手段,然而现有电感耦合等离子体发射光谱仪器(ICP-AES)功耗高、氩气消耗大,不能用于元素的现场分析。微等离子体具有小体积、低功耗、低气耗的特点,非常适于发展便携式发射光谱分析仪器~([1])。然而目前报道的介质阻挡放电(DBD)、液体阴极放电(SCGD)等在分析灵敏度方面仍不能满足As、Sb等测试需求,基于此我们开发了常压辉光放电微等离子体激发源(APGD),较好的解决了现有微等离子体源对氢气耐受力差、灵敏度低等不足,并在此基础上研发了基于APGD激发源的锂电池供电的便携式发射光谱仪样机,其具有绿色节能、高效检测、灵敏可靠、现场分析等众多优点。利用该便携式仪器样机,我们通过选取不同的进样方法开展了常压辉光放电发射光谱仪分析方法研究以更好地拓展其应用范围。下面以进样方法分类阐述:氢化物蒸气发生进样:选用硼氢化钾-酸体系使分析物生成氢化物或蒸气进入APGD检测,建立了As(砷)、Cd(镉)、Hg(汞)、Pb(铅)、Sb(锑)等元素灵敏检测方法,检出限范围为0.06-0.8μgL~(-1)。此外也验证了As、Sb、Hg多元素同时检测的可行性,该方法具有良好的检出限和稳定性~([2])。其他化学蒸气发生进样:选用抗坏血酸-盐酸体系、叁氯化钛-盐酸体系等分别还原亚硝酸根离子(NO2-)和硝酸根离子(NO_3~-)生成一氧化氮(NO)进入APGD检测,建立了NO_2~-和NO_3~-的检测方法~([3]),检出限为0.08μg mL~(-1)和0.05μg mL~(-1)(以N计)。此外还采用氧化蒸气发生将铵根离子(NH_4~+)氧化为氮气进入APGD检测,建立了NH_4~+的检测方法。紫外光蒸气发生进样:选用紫外灯照射以甲酸为基体的含Fe(铁)元素样品在线产生羰基铁蒸气进入APGD检测,建立了Fe元素的检出方法,方法检出限为2.1μg L~(-1)。综上所述,本文通过选用不同的样品引入体系展开了便携式常压辉光放电发射光谱仪分析方法研究工作。结果表明APGD激发光源可以很好的与化学蒸气发生或紫外光蒸气发生进样联用,从而实现对环境保护中高度关注的重(类)金属元素(As、Cd、Hg、Pb等),Fe元素,亚硝酸根及硝酸根离子等高效灵敏检测。(本文来源于《第五届全国原子光谱及相关技术学术会议摘要集》期刊2018-09-20)
李慎,郭颖,宫云舒,张菁,石建军[4](2018)在《脉冲调制占空比对常压射频辉光放电段特性影响的数值模拟》一文中研究指出射频放电段的起辉特性决定了常压脉冲调制射频辉光放电的放电特性和稳定性,通过建立常压氦气脉冲调制射频辉光放电的一维自洽流体数值模型,研究了射频放电段的放电时空演化过程,着重讨论了调制脉冲占空比对射频放电段的起辉过程和稳定放电特性的影响。当射频放电电压保持在680 V不变且占空比小于18.40%条件下,电子密度的空间分布表现为主等离子体均匀分布,射频放电段工作在起辉阶段;随着占空比的增长,射频放电段中的鞘层结构得到增强,在占空比大于18.4 0%条件下,电子密度的空间分布表现为电极两侧增强的双峰分布的情况,放电达到稳定状态。电子平均能量和电场强度的空间分布随占空比的变化规律,也揭示了射频放电段从起辉阶段到稳定放电状态的转变过程。研究结果为常压脉冲调制射频辉光放电的放电机制和稳定性控制提供了理论依据。(本文来源于《东华大学学报(自然科学版)》期刊2018年03期)
李豪,黄晓江,王墅[5](2017)在《He-O2常压双频辉光放电》一文中研究指出我们主要采用发射光谱研究了氦气中掺入少量氧气的常压双频辉光等离子体的特性。结果发现放电强度随着高频功率的增加而增加,但氧原子的密度随着高频功率的增加而减小;而放电强度和氧原子的密度都会随着低频功率的增加而增加。这种现象表明高频功率有利于氦原子的激发,但低频功率有利于产生活性氧原子。由于氧气的电负性,在工作气体中混入氧气会使放电强度减弱。加入0.3%氧气的混合气体会使氧原子的增加速率先增大后减小,这与激光诱导荧光法测量的结果一致。(本文来源于《第十八届全国等离子体科学技术会议摘要集》期刊2017-07-26)
丁薛璐,段忆翔[6](2014)在《微辉光放电等离子体常压质谱离子源》一文中研究指出常压开源质谱(Ambient Mass Spectrometry)的概念是由R.G.Cooks于2004.年首次提出的[1],由于其有无需真空条件的限制,无需进行样品预处理,可在常压的检测环境中直接对样品进行快速分析等特点,近年来该类离子化技术已作为质谱分析领域的一大研究热点而蓬勃发展。根据离子化过程的不同,可将常压质谱离子化技术分为喷雾技术、等离子体电离技术、光致电离技术,以及热辅助电离/解吸技术[2,3],其中基于等离子体的离子化技术由于其无溶剂化、清洁、高效、高灵敏度等优点而受到学者的追捧。最近,我们课题组报道了一种基于微辉光放电等离子体的常压质谱离子源(Microfabricated Glow Discharge Plasma,MFGDP)(图1)[4]。以常压微辉光放电为基础,MFGDP采用一种双电极放电构型,电极之间的距离小于1mm,用以维持氦、氩微等离子体的直流电功率低于4W。用MFGDP源产生的等离子羽清晰可见,等离子体气体温度接近室温,将等离子羽与样品表面直接接触也不会灼伤样品,因而MFGDP可达成对样品的无损伤分析。MFGDP具有优越的定性分析能力,可用于分析气态、液态、固态的纯样或复杂试剂样品,如非处方药品和香烟烟叶(图2)。在不与色谱联用,直接在开源环境下手动进样的条件下,以MFGDP对非那西丁、扑热息痛等样品做标线可得R~2值大于0.98,各样品8-10次重复手动进样所得RSD值在10%左右。我们相信,通过精确进样条件、优化等离子气体状态等一系列措施,MFGDP的定量分析能力还将进一步提升,同时,以MFGDP检测果蔬中的农药、有机挥发性气体等多方面的应用也正在拓展中。(本文来源于《中国化学会首届全国质谱分析学术研讨会会议论文集》期刊2014-04-26)
张定宗,王艳辉,刘富成,王德真[7](2013)在《裸露金属电极中的亚微秒脉冲常压辉光放电(英文)》一文中研究指出In order to better understand the physical mechanism of sub-microsecond pulsed glow discharge with bare metal electrodes,using a one-dimensional self-consistent fluid model,the properties of the discharge at atmospheric pressure are numerically studied.The results show that,a discharge without dielectric layers,i.e.a barrier free discharge,is extinguished only with the decrease of the applied voltage.Only one positive discharge event occurs at the slope of the pulsed voltage.A stable glow of barrier free discharge can be achieved only in short durations of the pulsed voltage.The barrier free discharge always starts with a subnormal glow discharge and then evolves into a normal glow discharge.Moreover,to control the discharge stabilization better,the effects of pulse repetition frequency,pulse duration,rising(front) and falling(slope) times on the discharge characteristics are investigated systematically.It is found that the discharge is comparatively more sensitive to the repetition frequency and the pulse duration,while little affected by the rising and falling times.(本文来源于《高电压技术》期刊2013年10期)
王莹莹[8](2013)在《脉冲调制常压射频介质阻挡辉光放电物理过程的数值模拟》一文中研究指出大气压射频辉光等离子放电可以在常压下进行,放电装置不受真空室尺度和形状的限制,便于连续化生产加工。操作简单、便携的优势使其在多个领域得到了广泛的应用,如材料表面改性、半导体刻蚀、有害物质处理、消毒等。尤其在生物医学方面的应用引起了人们更多的关注,常压等离子体可以直接作用于人或动物的身体,而这在低气压下是无论如何也实现不了的。然而,射频辉光放电过高的频率会导致放电不稳定,容易发生放电模式的转换:由均匀的辉光放电变成高温的弧光放电,不利于处理对温度敏感的材料,限制了大气压射频放电在工业生产中的应用。所以在高强度放电下控制放电的均匀稳定性问题成为了科学研究的重点。本文针对脉冲调制射频容性放电过程,建立自洽的一维无碰撞流体模型对放电进行数值模拟。模型中以氩气为背景气体,考虑了六种主要放电粒子和包括电离、激发等在内的十种反应。研究内容分为两部分:第一部分研究添加脉冲电源对等离子体放电特性的影响,主要研究脉冲开启阶段、放电稳定阶段、脉冲关闭阶段,脉冲对放电电压、电流密度、粒子密度、电子温度和电场强度的影响;第二部分重点探讨了不同放电参数下的放电特点。模型中改变的放电参数有脉冲占空比、脉冲开启时间、脉冲频率等。模拟结果表明,添加脉冲调制电源对放电起到了很好的控制作用。脉冲开启达到稳定后,时间平均的各粒子密度、电子温度以及电场强度的空间分布与没有脉冲调制的射频放电一致;脉冲开启(或关闭)时,放电电压和电流密度会及时响应并迅速增大(或减小);脉冲关闭后,粒子由于扩散作用会向两侧介质极板运动,但带电粒子不会完全消失,剩余的带电粒子会参与下一次放电的点火。固定脉冲关闭时间,改变开启时间对电子、氩亚稳态分子的时间平均分布影响较为明显,其密度会随着脉冲开启时间的增加而增大,但是对电子温度和电场强度几乎没有影响;当固定脉冲占空比20%时,改变脉冲频率,放电电流密度幅值在脉冲频率较低(<20KHz)时,电流密度幅值变化缓慢,当调制频率大于20KHz时,电流密度峰值迅速下降;当固定脉冲占空比90%时,改变脉冲频率,放电电流密度幅值的连线近似一条直线。(本文来源于《大连理工大学》期刊2013-05-05)
谢春香,张禹涛,马腾才[9](2012)在《常压辉光放电等离子体制备荧光碳纳米粒子》一文中研究指出采用常压辉光放电等离子体制备了超细荧光碳纳米粒子。分别采用聚乙二醇(PEG)2000和聚乙烯吡咯烷酮(PVP)20000作为表面活性剂和表面修饰剂,利用辉光放电等离子体射流产生的大量高能电子等活性粒子分解乙醇溶液制备碳纳米粒子。采用透射电子显微镜和荧光分光光度计对生成物的形貌和荧光特性进行了检测。结果表明,生成物为石墨相的荧光碳纳米颗粒。随着反应时间的延长,生成物的荧光强度增强;采用PEG-2000修饰后产物的荧光强度比采用PVP-20000更强;丝状放电模式下生成物的荧光强度高于辉光放电模式。制备的碳纳米颗粒的荧光量子产率为46.58%。(本文来源于《高分子材料科学与工程》期刊2012年08期)
钱宇骏,宋书通,丁可,张菁,石建军[10](2011)在《常压氩气脉冲调制介质阻挡辉光放电特性的数值模拟研究》一文中研究指出常压射频辉光放电产生的等离子体具有等离子体密度高、均匀稳定等特点,但同时产生的等离子体气体温度高,放电消耗功率高,特别是氩气常压射频辉光放电中放电强度较氦气中更高。最近提出了常压脉冲调制射频辉光放电一方面通过调制射频功率,降低了等离子体气体温度和射频功率消耗,另外实验研究也发现脉冲调制射频辉光放电技术可以在保持放电活性的前提下提高放电的均匀稳定性。但是由于诊断技术的匮乏,对其中的放电动力学过程和放电机理还缺乏深入研究。(本文来源于《第十五届全国等离子体科学技术会议会议摘要集》期刊2011-08-08)
常压辉光放电论文开题报告
(1)论文研究背景及目的
此处内容要求:
首先简单简介论文所研究问题的基本概念和背景,再而简单明了地指出论文所要研究解决的具体问题,并提出你的论文准备的观点或解决方法。
写法范例:
在30多种有毒金属元素中,镉(Cd)被列为最有毒的金属元素之一。近年来,我国农业环境镉污染日益严重,"镉大米"事件层出不穷。目前,传统的Cd检测分析方法以液体进样的光谱方法为主,但这些方法不仅仪器体积大、成本高,而且样品前处理耗时、费力。因此,发展一种快速可靠的大米Cd检测分析方法对大米产地准出、市场准入等环节监控具有重要的意义。微等离子体作为激发源在原子光谱分析领域引起了越来越多的关注,其中常压辉光放电~([1])(APGD)激发源因其体积小、功耗低、灵敏度高、供电电源简单等特点在便携式微型仪器的发展中具有一定的优势。另一方面,电热蒸发进样~([2])(ETV)因其样品引进效率高、进样量少、可实现基质分离和固体样品直接进样等优势成为原子光谱分析领域的一种良好的进样方式。本文采用电热蒸发钨丝捕获固体进样与常压辉光放电微等离子体发射光谱技术联用,建立了直接固体进样灵敏检测大米中Cd的方法。实验中探讨了灰化时间等条件的影响;考察了常见共存离子及有机基体对镉测定的干扰。该方法对大米中的Cd检出限为2.6 pg,加标回收率在94.0%~109.3%,多次测定的相对标准偏差为7.7%,可满足国家标准(GB2762-2017)对大米粮食中Cd限量的检测要求。通过对实际大米样和国家标准物质的对比检测,发现该方法检测结果与微波消解ICP-MS方法测试值无显着差别,证实了建立方法的可靠性。本文方法无需样品消解和基体改进剂及其他试剂,绿色环保,且体积小、功耗低成本低,灵敏度高、分析时间短,提供了一种新型的用于食品中重金属检测的微等离子体激发源便携式发射光谱仪器的技术方案。
(2)本文研究方法
调查法:该方法是有目的、有系统的搜集有关研究对象的具体信息。
观察法:用自己的感官和辅助工具直接观察研究对象从而得到有关信息。
实验法:通过主支变革、控制研究对象来发现与确认事物间的因果关系。
文献研究法:通过调查文献来获得资料,从而全面的、正确的了解掌握研究方法。
实证研究法:依据现有的科学理论和实践的需要提出设计。
定性分析法:对研究对象进行“质”的方面的研究,这个方法需要计算的数据较少。
定量分析法:通过具体的数字,使人们对研究对象的认识进一步精确化。
跨学科研究法:运用多学科的理论、方法和成果从整体上对某一课题进行研究。
功能分析法:这是社会科学用来分析社会现象的一种方法,从某一功能出发研究多个方面的影响。
模拟法:通过创设一个与原型相似的模型来间接研究原型某种特性的一种形容方法。
常压辉光放电论文参考文献
[1].杨春,姚思琪,郑洪涛,朱振利.常压辉光放电微等离子体激发源与光化学蒸气发生联用检测水体中的痕量铁[J].光谱学与光谱分析.2019
[2].邓绮思,杨春,朱振利.电热蒸发钨丝捕获固体进样-常压辉光放电微等离子体发射光谱测定大米中镉[C].第五届全国原子光谱及相关技术学术会议摘要集.2018
[3].杨春,关雪迪,姚思琪,郑洪涛,朱振利.便携式常压辉光放电发射光谱仪分析方法研究[C].第五届全国原子光谱及相关技术学术会议摘要集.2018
[4].李慎,郭颖,宫云舒,张菁,石建军.脉冲调制占空比对常压射频辉光放电段特性影响的数值模拟[J].东华大学学报(自然科学版).2018
[5].李豪,黄晓江,王墅.He-O2常压双频辉光放电[C].第十八届全国等离子体科学技术会议摘要集.2017
[6].丁薛璐,段忆翔.微辉光放电等离子体常压质谱离子源[C].中国化学会首届全国质谱分析学术研讨会会议论文集.2014
[7].张定宗,王艳辉,刘富成,王德真.裸露金属电极中的亚微秒脉冲常压辉光放电(英文)[J].高电压技术.2013
[8].王莹莹.脉冲调制常压射频介质阻挡辉光放电物理过程的数值模拟[D].大连理工大学.2013
[9].谢春香,张禹涛,马腾才.常压辉光放电等离子体制备荧光碳纳米粒子[J].高分子材料科学与工程.2012
[10].钱宇骏,宋书通,丁可,张菁,石建军.常压氩气脉冲调制介质阻挡辉光放电特性的数值模拟研究[C].第十五届全国等离子体科学技术会议会议摘要集.2011